Prerequisite product
Controller’s choice
Module installation
Wiring diagrams
On the heater power supply
Devices pairing
Each module will have to be paired to one same controller to permit to centralize the control. To pair a controller, refer to the user guide of the Multifunction Relay Switch.
On a pilot wire heating module
On a pilot wire heating module – at the electrical panel
Advanced mode - repeater
The activation of the repeater mode has to be made with the module under power supply.
When the repeater mode is activated, the Multifunction Relay Switch will repeat all the messages from EnOcean network, and so increase the range of the devices around it.
The repeater mode has 3 levels:
- Level 0: repeater mode is deactivated
- Level 1: the signal is repeated (1 jump, see figure 1)
- Level 2: the signal is repeated (2 jumps, see figure 1)
Warning: by default during the first installation the repeater mode is at level 0.
Incrementation of the three levels for repeater mode:
Repeater mode working principle (figure 1) :
Access to repeater’s next level:
Level 0 to level 1:
- Do 2 short presses.
- The module LED blinks twice in green, confirming the activation of repeater’s next level.
Level 1 to level 2:
- Do 2 short presses.
- The module LED blinks three times in green, confirming the activation of repeater’s next level.
Level 2 to level 0 (repeater mode is deactivated):
- Do 2 short presses.
- The module LED blinks once in green, confirming the repeater’s mode deactivation.
Technical support
You have a specific question or need help regarding the installation or use of your product? Contact us by email at rf.no1730813091don@t1730813091roppu1730813091s1730813091 or at +33 7 68 04 20 90.