Prerequisite product
Controller’s choice
Relay switch installation
Wiring diagrams
For a wired wall switch - single button
For a wired wall switch - double button
At the ceiling light
Without wired wall switch – 2 lights
At the electrical panel – NodOn DIN Rail Box is needed
Advanced mode - repeater
The repeater mode is requisite if two devices of the installation are 30 meters far away one from another.
The activation of the repeater mode has to be made with the module under power supply.
When the repeater mode is activated, the ON/OFF Lighting Relay Switch will repeat all the messages from EnOcean network, and so increase the range of the devices around it.
The repeater mode has 3 levels:
- Level 0: repeater mode is deactivated
- Level 1: the signal is repeated (1 jump, see figure 1)
- Level 2: the signal is repeated (2 jumps, see figure 1)
Warning: by default during the first installation the repeater mode is at level 0.
Incrementation of the three levels for repeater mode:
Repeater mode working principle (figure 1):
Access to repeater’s next level:
Level 0 to level 1:
- Do 2 short presses.
- The module LED blinks twice in green, confirming the activation of repeater’s next level
Level 1 to level 2:
- Do 2 short presses.
- The module LED blinks three times in green, confirming the activation of repeater’s next level.
Level 2 to level 0 (repeater mode is deactivated):
- Do 2 short presses.
- The module LED blinks once in green, confirming the repeater’s mode deactivation.
Devices pairing
To pair your controller with each of the modules installed, see the picture below. To pair a controller, please refer to the ON/OFF Lighting Relay Switch user guide.
Technical support
You have a specific question or need help regarding the installation or use of your product? Contact us by email at rf.no1730820122don@t1730820122roppu1730820122s1730820122 or at +33 7 68 04 20 90.